Kuryło, K.; Sabat, W.; Klepacki, D.; Kamuda, K. Comparison of Two Measurement Methods for the Emission of Radiated Disturbances Generated by LED Drivers. Energies 2022, 15, 9372. https://doi.org/10.3390/en15249372
Abstract:
The comparison of the results obtained using two methods for measuring the radio disturbance emissions produced by compact lighting drivers in the frequency range of 30 to 300 MHz has been presented in this paper. Any electrical and electronic equipment used within the EU must comply with Directive 2014/30/EC and harmonised standards. For lighting equipment, the dedicated standard is EN-IEC 55015:2019-11E. In this standard, for tests in the frequency range of 30 to 300 MHz, two equivalent test methods are allowed for lighting drivers, i.e., the traditional method in which disturbance emissions are measured in a semianechoic chamber SAC and the alternative CDNE (Coupling Decoupling Network Emission) method. Each method is characterised by a different measurement technique. For this reason, this paper aims to compare the results obtained by the two methods and to find out whether the CDNE and SAC methods, despite the difference in measurement technique, can be considered equivalent. The theoretical part of this study presents the results of an analysis of the literature on the subject and the technical aspects of measuring disturbance emission using both measurement methods. The practical part describes the construction of measurement stands for selected LED lamps and presents the measurement results and their statistical analysis.